N/A = No Information Available
DMP XR20 (continued)
DMP XR20 DSC Power 432 DSC PC1616 DSC PC1832 DSC Power 632 Ademco Vista-10P Ademco Vista 15P Napco GEM-P816 Napco GEM-P1632
GE Concord Express
60-806-95R-16Z
Bosch D4412
System Information
Reporting
Serial 3, CID, 4-2 N/A SIA - CID SIA - CID N/A
CID, Sescoa/Radionics,
Standard Pulse
Formats
CID, 4X2, Sescoa/
Radionics
CID, SIA CID, SIA SIA, CID Modem IIIa2/CID
Areas
4 1 0 0 1 1 1 1 1 0 2
Partitions
1 1 2 4 1 1 1 1 1 1 1
Arming Modes
Area/All-Perim/
Home-Sleep-Away
Stay/Away N/A N/A Stay/Away Stay/Away Stay/Away Stay/Away Stay/Away Stay/Away Stay/Away
Remote Access Compatible
Yes Yes Yes Yes Yes Yes (COMPASS) Yes (Compass) Yes Yes Yes Yes (RAM IV)
Phone Cable Monitor
Yes Yes Yes Yes Yes No Yes Yes Yes No Yes
Parts Compatible Across all Product Lines
Yes N/A N/A N/A N/A No No N/A N/A No No
Wireless Information
Wireless Arm/Disarm
Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes
Wireless Types Supported
Ademco -
Inovonics - ITI -
DMP 1100 Series
DSC DSC 433mHz DSC 433mHz DSC Ademco Ademco Gemini Gemini ITI DS
False Alarm Reduction Features
Cancel/Verify
Yes No No No No No No No No No No
Exit Error
Yes Yes N/A N/A Yes Yes Yes Yes Yes Yes Yes
Fire Verify Zones
Yes Yes N/A N/A Yes Yes Yes Yes Yes Yes Yes
Cross Zoning
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Abort Reporting
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
System Test by User
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
System Recently Armed
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Programmable Entry/Exit Delays
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Transmit Delay
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Swinger Zone Bypassing
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Report Bypass to Central Station
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Unique Duress Code
Yes Yes N/A N/A Yes Yes Yes Yes Yes Yes Yes
Call Waiting Cancel
Yes N/A N/A N/A N/A N/A N/A N/A N/A Yes Yes
Meets ANSI/SIA CP-01
Yes N/A Yes Yes N/A Requires Visa-10 PSIA Yes N/A N/A N/A N/A
LAN/WAN Network Communications
iCOMsl No Yes TL 250 Yes TL 250 No No No No No N/A
C944V2 Dialer
Capture Module
Internet Browser Interface
ePAD No Yes TL150 Yes TL150 No No No No No No No
Compliance
UL 365 Police Connected Burg
Yes N/A Yes Yes N/A No No N/A N/A No Yes
UL 609 Local Burglar
Yes N/A N/A N/A N/A No No N/A N/A No Yes
UL 1023 Household Burglar
Yes N/A Yes Yes N/A Yes Yes Yes Yes Yes Yes
UL 1076 Proprietary Burglar
Yes N/A N/A N/A N/A No No N/A N/A No Yes
UL 1610 Central Station Burg
Yes N/A Yes Yes N/A No No N/A N/A No Yes
UL 1635 Digital Burglar
Yes N/A N/A N/A N/A No No N/A N/A No Yes
UL 985 NFPA 74 Household Fire Warning
Yes N/A N/A N/A N/A Yes Yes N/A N/A Yes Yes
California State Fire Marshal (CSFM)
Yes Yes Yes Yes Yes
Requires Vista 10-
SIA varient
Yes N/A N/A Yes Yes
Made in U.S.A.
Yes No No No No No No No No No No