Digital Monitoring Products XT30/XT50 Installation Guide
16
ComPlIanCe
Listed Compliance Specications
20.1 Introduction
Theprogrammingandinstallationspecicationscontainedinthissectionmustbecompletedwheninstalling
theXT30/XT50inaccordancewithanyoftheANSI/ULburglarystandards.Additionalspecicationsmaybe
required by a particular standard.
20.2 Bypass Reports
ThebypassreportsmustbeprogrammedasYESforalllistedburglaryapplications.
20.3 Current Draw
Thetotalcurrentdrawfromacombinationofauxiliary,smoke,andbelloutputterminalsmustnotexceed
1.6 Amps.
20.4 Battery Standby
For24Hourbatterystandbyoperation,use9.0Ahbatteries.
20.5 Auxiliary and Bell Current
ForULlistedapplications,themaximumauxiliarycurrentis400mA,andthemaximumbellcurrentis500mA.
20.6 Cross Zoning
Eachzonemusthavethecapabilityofprotectingthecommonareaindividually.
20.7 Software Version
ForULlistedapplications,theminimumsoftwareversionmustbeVersion103.
Household Burglar-Alarm System Units
ANSI/UL 1023
21.1 Bell Cutoff
The bell cutoff time cannot be less than four minutes.
21.2 Entry Delay
Themaximumentrydelayusedmustnotbemorethan45seconds.
21.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
21.4 Wireless External Contact
Whenused,theExternalContactof1101,1102or1105mustbeprogrammedNormallyClosed.
21.5 Wireless Supervision Time
TheZoneInformationSupervisionTimecannotbesetto0(zero).
21.6 Wireless Audible Annunciation
TheWirelessAudibleoptionmustbeselectedasDAYforresidentialapplications.
21.7 Panel location
Mountpanelinsideprotectedarea.
21.8 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportatleastonceevery30days.
Digital Burglar Alarm Communicator System Units
ANSI/UL 1635
22.1 Entry Delay
The maximum entry delay used must not be more than 60 seconds.
22.2 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
22.3 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportonceevery24hours.