System Link User’s Guide
34
Modem
: Select this option if you are using a computer modem to dial a DMP 462FM
9600 Baud Modem Card installed on the panel or to the 2400 baud programming
dialer of an XR500 Series or XR100 Series panel.
Note: You must first configure your modem in System Link Configuration before
setting the Modem settings in the Panel Information window. See Modem Tab on
page
15 for information on configuring your computer’s modem.
Modem Special
: for XR500 Series (Version 112 or higher) and XR100 Series panel
communication requirements, when a slower baud rate that does not fluctuate is
needed to ensure data integrity. Modem Special allows this type of control when
using a computer modem to dial out.
Note: Only one modem can be used. Select the correct one for your operation.
Remote Key
: (Only operators with Administrator Authority can view the Remote Key.)
Enter a numerical code up to eight digits long that the panel should use as a password to
verify its identity to the System Link computer. The panel must give the correct key to
System Link before any programming may take place. All panels are shipped from the
factory with the key preset as blank.
Note: The programming options listed below vary according to what type of connection you
select in the Type field discussed above.
Phone
: Enter the phone number to dial to access the modem on the panel. This field
appears when you select SCS-1
/ SCS-105 or Modem in the Type field.
Note: If you need to dial a number to access an outside line, enter that number before the
panel's phone number. Also, enter a P for a pause after dialing the number to access the
outside line. For example, if you need to dial 9 to get an outside line, enter 9P then the
panel's phone number.
Note: Modems from some manufacturers require a comma (,) for a pause rather than the
letter P. Check your Modem documentation before entering the panel phone number.
Cfg Button:
Click the Cfg (Configure) button beside the Phone field to open a dialog box
that allows you to configure the 462FM. A pop-up window allows you to configure the
462FM. This button appears when you select Modem in the Type field.
Ring Count
: Enter the number of times the site phone rings before the 462FM
picks up. Enter a number between 1 and 15. The default is 1 ring. You must
increase the Dial Time Out in the Modem Tab about 10 seconds per ring.
Set Modem:
Click this button to dial the phone number programmed in Panel
Information. When the 462FM picks up, the Ring Count is stored in the 462FM
Module's programming. After the 462FM has stored the number, the 462FM
disconnects from System Link. A pop-up window appears stating, “Ring Count
successfully sent.”
Dial
: Select how you want the receiver to handle the phone line connection with the
panel. This field appears when you select SCS-1
/ SCS-105 or Modem in the Type field.
No
: Do not dial the panel phone number to make contact with the panel. This is
used mainly for multiplex and asynchronous accounts.
Yes
: Use the panel phone number entered in the Account Information file to dial
the subscriber's panel.