8
InstallatIon
6.7 XRSuper6/XR20/XR40 Standby Battery Calculations
Standby Battery Power Calculations Alarm Current
Command Processor Panel
ActiveZones1-9(1-5onXRSuper6)
ActiveZone10(Zone6onXRSuper6)
2-Wire Smoke Detectors
Panel Bell Output
x
x
x
50mA
1.6mA
4mA
0.1mA
______mA
______
______
______
Qty ______
Qty ______
Qty ______
1500mA
x
x
x
x
50mA
*2mA
30mA
0.1mA
Max.
______mA
______
______
______
______
1100D Wireless Receiver x 40mA ______ Qty ______ x 40mA ______
1100DI Wireless Receiver x 30mA ______ Qty ______ x 30mA ______
1100DH Wireless Receiver x 160mA ______ Qty ______ x 160mA ______
690/690F Security Command Keypad x 77mA ______ Qty ______ x 84mA ______
693 Security Command Keypad x 92mA ______ Qty ______ x 120mA ______
790/790F Security Command Keypad
ActiveZones(EOLInstalled)
x 77mA
1.6mA
______
______
Qty ______
Qty ______
x
x
84mA
*2mA
______
______
793 Security Command Keypad
ActiveZones(EOLInstalled)
x 92mA
1.6mA
______
______
Qty ______
Qty ______
x
x
120mA
*2mA
______
______
7060/7160 Thinline/7060A Aqualite Keypad x 72mA ______ Qty ______ x 87mA ______
7063/7163 Thinline/7063A Aqualite Keypad x 85mA ______ Qty ______ x 100mA ______
7360 Thinline Icon Keypad x 60mA ______ Qty ______ x 67mA ______
7363 Thinline Icon Keypad x 73mA ______ Qty ______ x 80mA ______
7070/7170 Thinline/7070A Aqualite Keypad
ActiveZones(EOLInstalled)
x 72mA
1.6mA
______
______
Qty ______
Qty ______
x
x
87mA
*2mA
______
______
7073/7173 Thinline/7073A Aqualite Keypad
ActiveZones(EOLInstalled)
x 85mA
1.6mA
______
______
Qty ______
Qty ______
x
x
100mA
*2mA
______
______
733WiegandInterfaceModule
ActiveZones(EOLInstalled)
x 30mA
1.6mA
______
______
Qty ______
Qty ______
x
x
30mA
*2mA
______
______
734WiegandInterfaceModule
ActiveZones(EOLInstalled)
x
x
15mA
1.6mA
______
______
Qty ______
Qty ______
x
x
15mA
*2mA
______
______
736P POPIT Interface Module
Radionics Popex, POPITs, OctoPOPITs
x
x
25mA
___mA
______
______
Qty ______
Qty ______
x
x
25mA
___mA
______
______
738A Ademco Wireless Interface Module x 75mA ______ Qty ______ x 75mA ______
708BusExtenderModule(onepair) x 20mA ______ Qty ______ x 20mA ______
710 Bus Splitter/Repeater Module x 30mA ______ Qty ______ x 30mA ______
714 Zone Expansion Modules
ActiveZones(EOLInstalled)
x
x
7mA
1.6mA
______
______
Qty ______
Qty ______
x
x
7mA
*2mA
______
______
712-8 Zone Expansion Module
ActiveZones(EOLInstalled)
x
x
17mA
1.6mA
______
______
Qty ______
Qty ______
x
x
17mA
*2mA
______
______
714-8, 714-16 Zone Expansion Module
ActiveZones(EOLInstalled)
x
x
20mA
1.6mA
______
______
Qty ______
Qty ______
x
x
20mA
*2mA
______
______
715 Zone Expansion Module
ActiveZones(EOLInstalled)
2-Wire Smokes
x
x
x
7mA
4mA
.1mA
______
______
______
Qty ______
Qty ______
Qty ______
x
x
x
7mA
*30mA
.1mA
______
______
______
715-8, 715-16 Zone Expansion Modules
ActiveZones(EOLInstalled)
2-Wire Smokes
x 20mA
4mA
.1mA
______
______
______
Qty ______ x 20mA
*30mA
.1mA
______
______
______
iCOM
s l
Network Alarm Communicator 80mA ______ Qty ______ 80mA ______
FA426 16-Point Receiver 47mA ______ 47mA ______
Aux. Powered Devices on Terminals 7 and 11
Other than Keypads and Modules
______mA ______mA
Total Standby
Total Standby______mA x number of Standby Hours
needed
Total Alarm
* Based on 10% of active zones in alarm condition.
______mA
______ =
______mA
+
Total
Total Alarm
________mA-hours
________mA-hours
________mA-hours
X .001
= ________Amp-hrs
______mA
Required
Vue de la page 13