XTL/XTLC Programming Guide Digital Monitoring Products
7
COMMUNICATION
3.10 Second GPRS APN (XTL Only)
Enter the second APN (Access Point Name). This works as a backup in case the rst APN
fails. The APN may contain two lines of 16 characters to equal 32 character Default is
set to SECURECOM400.
3.11 Receiver 1 Programming
Allows you to set the options for the rst receiver the panel attempts to contact when
sending reports. The XTL/XTLC supports communication to two receivers.
3.12 Alarm Reports
YES enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error, and
System Recently Armed reports to be sent to this receiver. Default is YES.
3.13 Supervisory/Trouble Reports
YES enables Supervisory, Trouble, Trouble Restoral, Force Armed, Late to Close, and
Fault reports to be sent to this receiver. Default is YES.
3.14 Opening/Closing and User Reports
YES enables Opening/Closing, Code Changes, and Bypass reports by user to be sent to
this receiver. Default is NO.
3.15 Test Report
Enter YES to enable the Recall Test report to be sent to this receiver.
3.16 First IP Address
Enter the rst (primary) IP address where the panel sends cell messages. Enter all
12 digits and leave out the periods. For example, enter IP address 192.168.0.250 as
192168000250. The periods display automatically.
The message is sent using rst GPRS APN and the rst IP Address. If no acknowledgment
is received, rst GPRS APN and the second IP address are used, followed, if needed, by
second GPRS APN and rst and second IP addresses, respectively.
3.17 First IP Port
Enter the rst IP port number to be used in conjunction with the rst IP Address. The
IP port identies the port used to communicate messages to and from the panel.
The default IP Port setting is 2001.
3.18 Second IP Address
Enter the second IP address where the panel sends network messages. Enter all 12
digits and leave out the periods. For example, enter IP address 192.168.0.250 as
192168000250. The periods display automatically.
3.19 Second IP Port
Enter the second IP port number to be used in conjunction with the second IP address.
The IP port identies the port used to communicate messages to and from the panel.
The default IP Port setting is 2001.
3.20 Receiver 2 Programming
Allows you to set the options for the second receiver the panel attempts to contact
when sending reports. The XTL/XTLC supports communication to two receivers. If you
select YES for any of the Receiver 2 options, you must have at least one IP address
programmed in Receiver 2 programming. Receiver 2 defaults are set to NO.
3.21 Alarm Reports
YES enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error, and
System Recently Armed reports to be sent to this receiver. Default is NO.
3.22 Supervisory/Trouble Reports
YES enables Supervisory, Trouble, Trouble Restoral, Force Armed, Late to Close, and
Fault reports to be sent to this receiver. Default is NO.
3.23 Opening/Closing and User Reports
YES enables Opening/Closing, Code Changes, and Bypass reports by user to be sent to
this receiver. Default is NO.
SECURECOM400
-
SECOND GPRS APN
RECEIVER 1 PROG
ALARM NO YES
SPV/TRBL NO YES
O/C USER NO YES
TEST RPT NO YES
FIRST IP ADDR
000.000.000.000
FIRST IP PORT
2001
SECOND IP ADDR
000.000.000.000
SECOND IP PORT
2001
RECEIVER 2 PROG
ALARM NO YES
SPV/TRBL NO YES
O/C USER NO YES
Vue de la page 13