Digital Monitoring Products XR20 Guide d'installation

Naviguer en ligne ou télécharger Guide d'installation pour Systèmes de contrôle d'accès de sécurité Digital Monitoring Products XR20. Digital Monitoring Products XR20 Installation guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Programming guide

Programming guideXrSuPer6/Xr20/Xr40 Command ProCeSSor™ PanelS

Page 2 - PROGRAMMING GUIDE

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide2inTroduCTion1.3 Programming MenuYou are now ready to start programming the XRSuper6

Page 3 - Table of ConTenTS

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products3inTroduCTion1.7 Keypads DMP offers multiple keypads in a variety of styles. All DM

Page 4

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide4inTroduCTionWhen there are more than four re sponse options avail able, press the CO

Page 5

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products5inTroduCTion1.11 Keypad Displays Current ProgrammingEach programming prompt display

Page 6 - Appendix 36

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide6iniTializaTionInitialization2.1 INITIALIZATION InitializationThis function allows yo

Page 7

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products7CommuniCaTionCommunication3.1 COMMUNICATION CommunicationThe Communication sectio

Page 8 - Revisions to this Document

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide8CommuniCaTion3.3 ACCNT NO: 12345 Account NumberEnter the account num ber sent to the

Page 9 - Introduction

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products9CommuniCaTion3.9 TEST TIME 00:00 AM PM Test TimePress COMMAND to enter the Tes

Page 10 - 1.6 Power Up

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide10CommuniCaTion3.18 RECEIVER 2 PROG Receiver 2 ProgrammingRepeat the instructions for

Page 11 - FRI 12:51 PM

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products11CommuniCaTion3.26 --SECOND PHONE NO. Second Telephone NumberThe panel dials the sec

Page 12 - 9 0 CMD

Digital Monitoring Products XRSuper6/XR20/XR40 Programming GuidebMODEL XRSuper6/XR20/XR40 COMMAND PROCESSOR PROGRAMMING GUIDEWhen using the Series XR

Page 13

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide12remoTe oPTionSRemote Options4.1 REMOTE OPTIONS Remote Options This section allows y

Page 14 - Initialization

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products13remoTe oPTionS4.7 SERV REC NO YES Service Receiver AuthorizationYES enables remot

Page 15 - Communication

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide14SySTem rePorTSSystem Reports5.1 SYSTEM REPORTS System Reports This function allows

Page 16

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products15SySTem oPTionSSystem Options6.1 SYSTEM OPTIONS System OptionsThis section allows yo

Page 17

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide16SySTem oPTionS6.6 EXIT DELAY: 60 Exit DelayEnter the Exit Delay time for all Exi

Page 18

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products17SySTem oPTionS6.11 ZN ACTY HOURS: Zone Activity HoursThis option allows you to moni

Page 19

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide18SySTem oPTionS6.15 HOUSE CODE: 0 House CodeWhen using a DMP wireless system, ente

Page 20 - Remote Options

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products19ouTPuT oPTionSBell Options7.1 BELL OPTIONS Bell OptionsThis section allows you to p

Page 21 - Remote Disarm

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide20ouTPuT oPTionSOutput Options8.1 OUTPUT OPTIONS Output OptionsThis section allows yo

Page 22 - System Reports

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products21ouTPuT oPTionS8.7 ENTRY OUT: 0 Entry OutputThis output turns on at the start of

Page 23 - System Options

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring ProductsiTable of ConTenTSIntroduction ...

Page 24

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide22ouTPuT oPTionS8.14 LATE CLS OUT: 0 Late To Close Output (XR20/XR40 Only)Enter th

Page 25

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products23ouTPuT informaTionOutput Information9.1 OUTPUT INFO Output InformationThis sect

Page 26

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide24area informaTionArea Information10.1 AREA INFORMATION Area Information (XR20/XR40 O

Page 27 - Bell Options

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products25zone informaTion Zone Information11.1 ZONE INFORMATION Zone InformationThis allows

Page 28 - Output Options

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide26zone informaTionFI PN EM SVA1 A2 FV AR-- NT DY EX Blank, Night, Day, or Ex

Page 29

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products27zone informaTion 11.7.1 STYLE: TOGGLE StyleThis option species the style

Page 30 - Arm-Alarm Output

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide28zone informaTion11.9 WIRELESS NO YES WirelessSelect YES to program this zone as a

Page 31 - Output Information

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products29zone informaTion 11.9.3 SUPRVSN TIME: XX Supervision TimePress any top row key to

Page 32 - Area Information

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide30zone informaTion11.10.3 SUPRVSN TIME: 0 Key Fob Supervision TimePress any top row

Page 33 - Zone Information

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products31zone informaTion 11.10.8 PRESS TIME: XXXXX Button Press TimeThis option species

Page 34

Digital Monitoring Products XRSuper6/XR20/XR40 Programming GuideiiTable of ConTenTS3.27 PagerIdenticationNumber ...

Page 35

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide32zone informaTion11.11 ALARM ACTION . . . Alarm ActionThe Alarm Action section allow

Page 36 - Serial Number Entry

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products33zone informaTion 11.12.3 ACTION: Output ActionEntering an Output Number displays th

Page 37

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide34zone informaTion11.16 CRS ZONE NO YES Cross ZoneSelect YES to enable cross-zoning

Page 38

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products35Stop12.1 STOP Stop At the STOP prompt, pressing any Select key allows you to exit t

Page 39 - Output Number

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide36aPPendiXAppendixThis section of the XRSuper6/XR20/XR40 Programming Guide provides a

Page 40

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products37aPPendiX14.4 Manual Telephone Line Seizure for Remote ProgrammingThis feature allo

Page 41

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide38aPPendiX14.5 Using the Walk TestThe XRSuper6, XR20, and XR40 panels provides a wal

Page 42

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products39aPPendiX14.6 Keypad Speaker OperationWhen using LCD Keypads, the panel provides di

Page 43 - Set Lockout Code

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide40aPPendiXThe third column from the left is the second digit of the 2-digit event cod

Page 44 - Appendix

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products41aPPendiX14.9 FA426 Wireless OperationThe FA426 is a 900MHz wireless receiver that

Page 45

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring ProductsiiiTable of ConTenTS8.4 Fire Alarm Output ...

Page 46

Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide42aPPendiX14.10 Zone Type DescriptionsThis section describes applications for the de

Page 47 - 14.7 Cross Zoning

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products43aPPendiX14.11 Zone Type DefaultsThe XRSuper6/XR20/XR40 panel contains 11 default z

Page 48

800-641-4282www.dmp.comMade in the USAINTRUSION • FIRE • ACCESS • NETWORKS2500 North Partnership BoulevardSpringfield, Missouri 65803-8877LT-0305 1.02

Page 49

Digital Monitoring Products XRSuper6/XR20/XR40 Programming GuideivTable of ConTenTS11.12.2 Output Number ...

Page 50 - 14.10 Zone Type Descriptions

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring ProductsvTable of ConTenTSThis page intentionally left blank.

Page 51 - 14.11 Zone Type Defaults

Digital Monitoring Products XRSuper6/XR20/XR40 Programming GuidevireviSionSRevisions to this DocumentThis section explains the changes that made to t

Page 52

XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products1inTroduCTionIntroduction1.1 Before You BeginBefore starting to program, we recommen

Commentaires sur ces manuels

Pas de commentaire