Vue de la page 42
XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products
35
Stop
12.1
STOP
Stop
At the STOP prompt, pressing any Select key allows you to exit the programmer
function of the XRSuper6/XR20/XR40 panel. When selected, the panel performs an
internal reset and exits the programmer. The Stop function causes the following
conditions to occur:
The system is DISARMED
All 1100 Series DMP Wireless transmitters are reset to NORMAL
The panel’s Status List is CLEARED
During the Stop function, all keypad displays are momentarily blank for two
seconds. Afterwards, the programming function is terminated and the keypads
return to the Status List display.
Power Up
When the SIA CP-01 option in System Options is set to Yes, for 60 seconds after
power up or after resetting the panel, any zone transitions are not recognized.
Normal zone processing resumes at the end of the 60 seconds.
SeT loCkouT Code
Set Lockout Code
13.1
SET LOCKOUT CODE
Set Lockout Code
Pressing COMMAND at the Stop prompt displays SET LOCKOUT CODE. This feature
allows you to program a special code that will then be required to gain access to
the panel’s internal Programmer through the keypad.
Changing the Lockout Code
You can change this code at any time to any combination of numbers from 1 to 5
digits long (1 to 65535). Do not use leading zeros for the lockout code.
1. Press any Select key. The display changes to ENTER CODE: -.
2. Enter a 1- to 5-digit code (do not enter a number higher than 65535). Press
COMMAND.
3. Enter the new Lockout Code again. Press COMMAND. The keypad display
changes to CODE CHANGED.
Once you have changed the code, it is important that you write it down somewhere
and store it in a safe place. Lost lockout codes require the panel to be sent back
into DMP for repair. You may cancel a Lockout Code by entering 00000 at the Set
Lockout Code command prompt.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.