1912XR Installation Guide
Digital Monitoring Products, Inc. 1912XR Installation Guide
Page 5
System Components
3.1 Description
The DMP 1912XR system is made up of an alarm panel with built in communicator, an enclosure, and a
16.5 VAC transformer. You can add up to eight Security Command keypads, an expansion interface
module, loop and output expanders, and initiating and indicating circuit modules. You can also connect
auxiliary devices to the panel's output relays to expand the basic system. Combined current requirements
of additional modules may require an auxiliary power supply. Refer to section 7.6 in this manual when
calculating power requirements.
3.2 Wiring diagram
The 1912XR system below shows some of the accessory modules you can connect for use in various
applications. A complete description of each module follows.
3.3 Lightning protection
Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on input and
output circuits of the 1912XR. Additional surge protection is available by installing the DMP 370 or 370RJ
Lightning Suppressors.
Figure 3: 1912XR wiring diagram
AC BELL
AC
1
2
34 5678 9
10
11
12
13
14 15
16
17 18 19
GND
RED YEL GRN BLKB + B - SMK L5+ L5- L1 L2 L3 L4GNDGND
1k
3.3k Resistor
DMP Model 309
1k
1k
J4
Dual Line Expansion
J10
Battery Only Restart
J16
Command Processor Reset
J9
EPROM Socket
1k
1k
1k
1k
LOOP EXPANDER
Model 714
15mA at 12 VDC
J15
K9
K5
Connects auxiliary power
to common of Output 1.
Loop 5 and all expanded loops are suitable for installation as Class
B (as applicable for the initiating and signaling line circuits per UL
864 Table 48.2 or 48.3), Central Station Type 1, Type 2, or Type 3
multiplex system. Installation limits under jurisdiction of local
authority.
RED
BLACK
22 GA. MIN
GREEN
22 GA. MIN
BLACK
22 GA. MIN
YELLOW
22 GA. MIN
RED
Maximum AC wire distance
With 16 gauge wire: 70 feet
With 18 guage wire: 40 feet
DMP transformers:
Model 320
16.5 VAC 40VA
wire-in,
Model 321
16.5 VAC 40VA,
Model 322
16.5 VAC 100VA,
wire-in.
Wire-in is required
for NFPA 72.
Keypads
Model 670, 770, 771
100mA at 8 to 16 VDC
125mA with display lit.
Cold Water Pipe
Earth Ground
Yellow
Red
Green
Black
16 to 18 gauge wire
Heat detectors, manual pull
stations, or any other UL listed
shorting device. Unlimited
number of units.
Bell
12 VDC nominal
Total current 1 Amp max.
Refer to LT-0164 for list
of approved indicating
devices.
Central Station System
Supplemental device.
Local System
Requires 866 Indicating
Circuit Module.
Household System
An alarm sounding device
must be installed indoors
so that it is clearly heard
in all sleeping areas.
Plug into
120 VAC
outlet not
controlled
by switch.
Keyswitch Arming Loop
May be connected to any loop.
See section 12.4.
+
1k
DMP Model 310
Smoke
Detector
Power
Supervision
Relay
Secondary Power Supply
1.2 Amps max. charging current.
Use only 12 VDC rechargable
batteries. DMP Model 367.
Replace every 3 to 5 years.
Output Header J2
All outputs must be connected to devices located
within the same room as the panel.
Relay Output 1
Use Model 305
Relay Output 2
Use Model 305
K2
J11 J12
Ground Start Relay
Use Model 305
DD, MPX
Selection
Rear Tamper
Front Tamper
Tamper Header
1k
1k
ARM
DISARM
1k
1k
Refer to LT-0164 for a list of approved
4-wire smoke detectors and power
supervision relays.
Tamper protection
when required for
Model 349A Attack
Resistant Enclosure.
For Sprinkler Supervision,
Normally Open devices
must be used.
3.3k
3.3k
3.3k 3.3k
LOOP EXPANDER
Model 715
25mA at 12 VDC
LOOP 5
LOOP 1
LOOP 2
LOOP 3
LOOP 4
Expansion Connector
AC wiring must be in
conduit and exit out the left
side of the panel enclosure.
Wiring on terminals 5 through 17 must exit
to the right and maintain a 1/4" separation
from the AC and battery positive wiring.
Refer to the 715 Installation Sheet (LT-
0162), or the smoke detector
manufacturer's compatibility guide, for
a list of approved detectors.
For power limited systems