28 XR150/XR350/XR550 User’s Guide User Menu
Using the Bypass Zones Function
1. Access the User Menu.
2. PressCOMMANDuntilBYPASSZONES?displays.
3. Press any Select key. The keypad displays
ZONE:-RSTBYPS.
4. ToBypassazone,enterthezonenumberandselectBYPS.
Thezonenumberautomaticallydisappearsandanewzone
number can be entered. Refer back to step 3.
5. ToResetazone,enterthezonenumberandselectRST.
Browser Feature
If you are unsure of the zone number or description, refer to
Appendix B at the back of this guide for a diagram showing you
how to use the built-in Bypass Zones browser.
Zone Monitor
Allows the system to monitor selected disarmed zones (doors,
windows, or motion detectors) and display their name at the
keypad as they are faulted. This feature could be used to monitor
an access door.
Zone Monitor works with any disarmed zone and also sounds the
keypadmonitortonewhenthezonefaults.Thezonenamedisplays
at all keypads designated for the area in your system.
YoucanplaceanycombinationofdisarmedzonesinZoneMonitor
butonlythemostrecentzonefaulteddisplays.Thedisplayedzone
nameclearsautomaticallyafterashorttimeorwhenthezoneis
armed.
Monitor (Chime) Shortcut Key
All Systems — Press 5 for 2 seconds when the system is disarmed.
Thisinitiates the Zone Monitor operation forall Exit zones in an
Area system or all zones assigned to the perimeter in a Home/
Sleep/Away, Home/Sleep/Away with Guest, or All/Perimeter
system.Thekeypad displays MONITORONandchimes or displays
MONITOROFFandnotoneissounded.
Testing your system’s burglary protection
After using the System Test function, place all zones in Zone
Monitor. Starting at the front door, go around and open and then
close each door and window. You should hear the keypad beep
eachtime.Thekeypadalsodisplaysthenameofeachzoneasits
device is opened.
Oncethe protected doors and windows test is complete, walkin
frontofeachmotiondetector.Thekeypadshouldbeeptoconrm
the zone has tripped. If at any time during your weekly testing
a device does not cause the keypad to beep, call the service
department for assistance.
Using the Zone Monitor Function
1. Access the User Menu.
2. PressCOMMANDuntilZONEMONITOR?displays.
3. Press any Select key. The keypad displays ALL NBR or
PERIM ALL NBR.
4. Select PERIM to place all disarmed perimeter zones into
Zone Monitor.
4a. The keypad displays ALL? ADD RMV.
4b. SelectADDtoaddalldisarmedzonestoZoneMonitor.
4c. SelectRMVtoremovealldisarmedzones.