10
InstallatIon
6.8 XR100 Series Canadian Power Requirements
During AC power failure, the XR100 Series panel and all connected auxiliary devices draw their power from the battery.
All devices must be taken into consideration when calculating the battery standby capacity. The following table lists the
XR100 Series panel power requirements. You must add the additional current draw of keypads, zone expansion modules,
smoke detector output, and any other auxiliary devices used in the system for the total current required. The total is then
multiplied by the number of standby hours required to calculate the total ampere-hours required.
Standby Battery Power Calculations Standby Current Alarm Current
XR100 Series Control Panel
Relay Outputs 1-2 (ON)
Switch Grounds 3-6 (ON)
Active Zones 1-8
Active Zones 9-10
2-Wire Smoke Detectors
Panel Bell Output
Qty 1 _
Qty _______
Qty _______
Qty _______
Qty _______
Qty _______
x
180mA
30mA
5mA
1.6mA
4mA
0.1mA
180 mA
______
______
______
______
______
Qty 1 _
Qty _______
Qty _______
Qty _______
Qty _______
Qty _______
x
180mA
30mA
5mA
2mA*
30mA
0.1mA
1500mA
180 mA
______
______
______
______
______
______mA
893A Dual Phone Line Module Qty _______ x 12mA ______ Qty _______ x 50mA ______
462N Network Interface Card Qty _______ x 50mA ______ Qty _______ x 50mA ______
481 Expansion Interface Card Qty _______ x 15mA ______ Qty _______ x 15mA ______
464-263H HSPA+ Cellular Communicator Qty _______ x 15mA ______ Qty _______ x 48mA ______
1100X Wireless Receiver Qty _______ x 46mA ______ Qty _______ x 46mA ______
1100XH Wireless High Power Receiver Qty _______ x 160mA ______ Qty _______ x 160mA ______
860 Relay Output Module (one relay active)
All four relays active
Qty _______ x
34mA
138mA
______
______
Qty _______ x
34mA
138mA
______
______
865StyleWorXNoticationModule Qty _______ x 26mA ______ Qty _______ x 85mA ______
866StyleWNoticationModule Qty _______ x 45mA ______ Qty _______ x 76mA ______
867LX-BusStyleWNoticationModule Qty _______ x 30mA ______ Qty _______ x 86mA ______
869 Dual Style D Initiating Module Qty _______ x 25mA ______ Qty _______ x 75mA ______
7060/7160 Thinline/7060A Aqualite Keypad Qty _______ x 72mA ______ Qty _______ x 80mA ______
7063/7163 Thinline/7063A Aqualite Keypad Qty _______ x 85mA ______ Qty _______ x 100mA ______
7070/7170 Thinline/7070A Aqualite Keypad
Active Zones (EOL Installed)
Qty _______ x
72mA
1.6mA
______
______
Qty _______
Qty _______
x
x
87mA
2mA*
______
______
7073/7173 Thinline/7073A Aqualite Keypad
Active Zones (EOL Installed)
Qty _______ x
85mA
1.6mA
______
______
Qty _______
Qty _______
x
x
100mA
2mA*
______
______
7872 Graphic Touchscreen Keypad
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
145mA
1.6mA
______
______
Qty _______
Qty _______
x
x
215mA
2.0mA
______
______
7873 Graphic Touchscreen Keypad
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
143mA
1.6mA
______
______
Qty _______
Qty _______
x
x
243mA
2.0mA
______
______
734 Wiegand Interface Module
Active Zones (EOL Installed)
Annunciator (ON)
Qty _______
Qty _______
x
x
15mA
1.6mA
______
______
Qty _______
Qty _______
Qty _______
x
x
x
15mA
2mA*
20mA
______
______
______
734N Wiegand Interface Module
Active Zones (EOL Installed)
Annunciator (ON)
Wiegand Reader
Qty _______
Qty _______
Qty _______
x
x
x
146mA
1.6mA
200mA
______
______
______
Qty _______
Qty _______
Qty _______
Qty _______
x
x
x
x
148mA
2mA*
20mA
200mA
______
______
______
______
734N-WiFi Wiegand Interface Module
Active Zones (EOL Installed)
Annunciator (ON)
Wiegand Reader
Qty _______
Qty _______
Qty _______
x
x
x
146mA
1.6mA
200mA
______
______
______
Qty _______
Qty _______
Qty _______
Qty _______
x
x
x
x
148mA
2mA*
20mA
200mA
______
______
______
______
Copy Sub-Totals to next page
Sub-Total Standby
*
Based on 10% of active zones in alarm.
______mA Sub-Total Alarm ______mA