XR100 Series Canadian Installation Guide Digital Monitoring Products
17
InstallatIon
J23 6-Pin Header
14.1 Description
TheXR100SeriesCanadianpanelsupportsDirectProgramming,LX-Bus,and,DMPWirelessoperation.Onlyoneoperation
can function at a time. Install a jumper on one pair of J23 header pins to indicate how the panel is programmed to
operate.RefertothetablebelowwheninstallingajumperonJ23.Whenajumperisinstalledormovedonthe6-pin
header,brieyresetthepanelusingtheJ16jumpertoactivatetheselectedoperation.
Note:Onlyoneoperation,DirectProgramming,LX-Bus,orDMPWirelesscanfunctionatatime.
J23 6-pin Header
Letter Operation
R Direct Programming
L LX-Bus
X 1100SeriesDMPWireless
J22 LX-Bus Expansion Connector
15.1 Description
TheXR100SeriesCanadianpanelsupportsoneLX-Buscircuitthatprovides100expansionzones,DMPWirelessthat
provides 100 wireless zones, or direct connect programming. Enable J22 LX-Bus Header to use the 100 expansion or
wireless zones.
15.2 J22 LX-Bus Header
Note:Onlyoneoperation,DirectProgramming,LX-Bus,orDMPWirelesscanfunctionatatime.SeetheConnectingLX-Bus
andKeypadBusDevicessectionformaximumwiringdistances.
For each connection, respect wire colors when connecting devices and use all four wires. After placing the jumper on the
J236-Pinheadertoenabletherequiredoperation,brieyresetthepanelusingtheJ16jumpertoactivateoperation.
Wireless Bus Operation:Placeajumperonthetwopinsnexttotheletter“X”ontheJ236-Pinheader.WhenusingJ22as
awirelessbus,connectaDMPModel3004-wireHarnesstotheJ224-pinheaderlabeledLX.Connecttheotherendtothe
J3headeronthe1100Xor1100XHWirelessReceiver.Thisprovidesupto100wirelesszonesnumbered500to599.Referto
the1100XWirelessReceiverInstallGuide(LT-0708)orthe1100XHWirelessReceiverInstallGuide(LT-0970).
LX-Bus Operation:Placeajumperonthetwopinsnexttotheletter“L”ontheJ236-pinheader.WhenusingJ22asanLX-
Bus,connectaDMPModel3004-wireHarnesstotheJ226-pinheaderlabeledLX.Thisprovides100LX-Buszonesnumbered
500-599.
Note: Do NOT use shielded wire when using the LX-Bus.
Direct Programming Operation:Placeajumperonthetwopinsnexttotheletter“R”ontheJ236-Pinheader.Whenusing
J22asadirectprogrammingport,connectathe4-wireconnectorfromDMPModel399HarnesstotheJ224-pinheader
labeled LX. Connect the Model 399 DB-9 connector onto an RS-232 port on a Laptop computer. This allows direct panel
programming from the attached computer.
15.3 LX-Bus Interface Cards
YoucanaddoneInterfaceCard(Model481,462Nor464-263H)totheXR100SeriesusingJ6InterfaceCardConnector
located on the board right edge. The Interface Cards provide up to 100 LX-Bus Zones. Refer to the following table to
identify zone locations and numbers relative to J22 operation.
J22 LX-Bus Enabled (Set
J23 to “X”)
AND
One Interface Card
Wireless-
Bus
Zone Numbers LX-Bus Zone Numbers
1 500-599 1 500-599
15.4 LX-Bus LEDs
ThetwoLEDs,locatednearthebottom-rightcornerofJ21indicatedatatransmissionandreceipt.ThetopLEDashes
greentoindicatethepanelistransmittingLX-Busdata.ThebottomLEDashesyellowtoindicatethepanelisreceiving
LX-Bus data.
15.5 OVC LED
TheOvercurrentLED(OVC)lightsRedwhenthedevicesconnectedtotheKeypadBusandLX-Bus(es)drawmorecurrent
thanthepanelrating.TheOVCislocatedaboveOutputs1and2onthepanelandturnsasteadyRedwhenlit.Whenthe
OVCLEDlightsRed,theLX-Bus(es)andKeypadbusshutdown.
Figure 7: J23 6-pin Header
LEDs
Xmit
Receive
J22
LX
Overcurrent
LED
J23
R
L
X