XRSuper6/XR20/XR40 Programming Guide
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
6.1 SYSTEM OPTIONS
This section allows you to select system wide parameters used in the operation of
the XRSuper6/XR20/XR40 system. A description of each System Option follows:
6.2 MODE
This configures the panel as either a four Area system (XR20/XR40 only), an All/
Perimeter system (Perimeter/Interior), or a Home/Away system (Perimeter, Interior,
and Bedrooms). Zones must be assigned to Bedrooms for the area to be active.
6.3 CLOSING CODE
When YES is selected, a code number is required for system arming. If NO is
selected, a code number is not required for system arming.
6.4 CLOSING CHECK (XR20/XR40 Only)
Select YES to enable the panel to verify that all areas have been armed after a
schedule expires. If the Closing Check finds any areas disarmed past the scheduled
time, all keypads emit a steady beep and display CLOSING TIME!.
6.5 ENTRY DELAY 1
Enter the entry delay time for all exit type zones programmed to use Entry Delay 1.
When an armed Exit type zone is faulted, the keypad prewarn tone begins sounding
and ENTER CODE:- displays on all keypads.
The area must be disarmed before the delay expires or an alarm report is sent to the
receiver. All Burglary type zones in all areas are delayed along with the exit type
zone. Entry delay times can be from 1 to 250 seconds. Repeat the above for Entry
Delay 2 if it is being used.
6.6 EXIT DELAY
Enter the Exit Delay time for all Exit type zones. When the system is armed, this
Exit Delay time starts and all activity on Exit and Burglary zones is ignored until the
exit delay expires. The delay countdown shows on the keypad for the user. If an
exit zone is in a bad condition at the end of the exit delay:
the alarm bell sounds for 2 seconds
an Exit Error report is sent to the alarm receiver
the bad exit zone is force armed
If any other zone is in a bad condition at the end of the Exit Delay, an alarm on that
zone is indicated. The Exit Delay time can be from 1 to 250 seconds. Enter zero to
disable the Exit Delay feature.
6.7 CROSS ZONE TIME
Enter the time allowed between zone faults. When a zone programmed for cross
zoning faults, the panel begins counting down the Cross Zone Time you enter here.
If the same zone or another zone faults within this time, an alarm report is sent to
the receiver.
If the Cross Zone Time expires without the second zone fault, only a zone fault
report from the first zone is sent to the receiver. The Cross Zone Time can be from
4 to 250 seconds in one second increments. Enter zero to disable the Cross Zone
Time feature.
6.8 POWER FAIL DELAY
This option tracks the duration of an AC power failure. When the AC power is off for
the length of the programmed delay time, an AC power failure report is sent to the
receiver. The delay time can be from 1 to 9 hours. Entering a zero sends the AC
power failure report within 15 seconds.
SYSTEM OPTIONS
EXIT DELAY: 45
ENTRY DLY 2: 60
ENTRY DLY 1: 30
CLS CHK NO
CLS CODE NO
AREA A / P H / A
MODE: ALL/ PERIM
SYSTEM OPTIONS
CRS ZONE TM: 0
PWR FAIL HRS: 1