XR100 Series Programming Guide Digital Monitoring Products
23
Remote options
7.6
PC MODEM NO YES
PC Modem
YESallowsthepaneltoanswerthetelcolinkandconnectwithRemoteLink
throughthePCModemat2400baud.NOdisablesPCModemcommunication.
7.7
ALR RCVR NO YES
Alarm Receiver Authorization
SelectYEStoenableremotecommandsandprogrammingtobeacceptedfromthe
alarmSCS-1RReceiver.TheRemoteKeyoptioncanalsoberequired.
WithYESselected,thepanelrequeststhereceiverkeyduringitsrstcommunication
withtherstSCS-1RReceiver.Thepanelretainsthisalarmreceiverkeyinmemoryand
allows remote commands to be accepted from the alarm receiver. If an alarm occurs
during a remote connect, the alarm report is immediately sent to this receiver only.
When NO is selected, remote commands and programming are not accepted from the
alarmSCS-1RReceiver.
7.8
SVC RCVR NO YES
Service Receiver Authorization
YESenablesremotecommandsandprogrammingtobeacceptedfromasecondary
servicereceiverotherthanthealarmSCS-1RReceiver.TheRemoteKeyoptioncanalso
be required.
WithYESselected,thepanelrequeststheservicereceiverkeythersttimeitis
contacted by the service receiver. The panel retains this service receiver key in memory
and accepts remote commands from the service receiver.
If an alarm occurs during a remote connect, the panel disconnects from the service
receiver and calls the alarm receiver. Alarm reports are only sent to the alarm receiver.
It is important that the alarm receiver key and the service receiver key programmed
at the central station are NOT the same so the panel can determine the difference
between receivers.
When NO is selected remote commands and programming are not accepted from a
secondary service receiver.
ThisoptionmustbeYEStoallowprogrammingfromadirectlyconnectedcomputeror
aniCOM/iCOM-E.
7.9 Manufacturer Authorization
SelectYEStoallowDMPTechnicalSupporttechnicianstoaccessthepanelduring
system service or troubleshooting. This authorization automatically expires within
one hour.
DMP remote service is provided on a read only basis: DMP technicians can look
at the system programming and make suggestions only. Alterations can only be
accomplished by installing company service personnel.
7.10 Allow Network Remote
Thisoptiondisplaysonlyifthepanelhasnetworkcapability.YESallowsremote
programming over the network. Changing this option does not change any other
networkprogrammingoptions.DefaultisYES.
7.10.1
NETWORK PROG
Network Programming Port
PORT: 2001
Entertheprogrammingportnumber.Theprogrammingportidentiestheportused
to communicate messages from the panel. The default Programming Port setting is
2001.
7.10.2 Encrypt Network Remote
YESencryptsdatasentovernetwork.DefaultisNO.
7.11 Allow Cellular Remote
YESallowsremoteprogrammingusingcellularconnection.DefaultisYES.
7.11.1 First GPRS APN
EntertherstAPN(AccessPointName).Thisallowsanaccesspointforcellular
communication and is used to connect to a DNS network. The APN may contain two
linesof16characterstoequal32characters.DefaultissettoSECURECOM400.
Second GPRS APN
EnterthesecondAPN(AccessPointName).Thisworksasabackupincasetherst
APNfails.TheAPNmaycontaintwolinesof16characterstoequal32characters.
DefaultissettoSECURECOM400.
SECURECOM400
-
FIRST GPRS APN
AUTH? NO YES
ALLOW NETWORK
REMOTE? NO YES
MANUFACTURER
ENCRYPT NETWORK
REMOTE? NO YES
ALLOW CELL
REMOTE? NO YES
SECURECOM400
-
SECOND GPRS APN