34 XR150/XR350/XR550 User Guide User Menu
Browser Feature
If you are unsure of the zone number or description, refer to
Appendix B at the back of this guide for a diagram showing you
howtousethebuilt-inZoneStatusbrowser.
Bypass Zones
Allowsyoutobypassazonepriortoarming.
Bypassing is usually done when a zone cannot be restored to
normal.Asignicantbenetofbypassingazoneistoallowazone
in a faulted or bad condition to be bypassed so arming can occur.
Thefaultedzonecanbeservicedthenextday.
A zone can be bypassed only while it is disarmed. Fire, panic,
emergency,andsupervisorytypezonesarealwaysarmed,sothey
can never be manually bypassed.
Bypass Zones can also be used to reset a zone that has been
bypassed and restore it back into the system.
When Bypass Zones is selected, a report can be transmitted to
your central station.
During arming, when choosing to bypass a zone or device, there
may be a pre-programmed maximum number of zones (up to
8) that can bebypassed in an area. This limitis programmed at
installation.
Using the Bypass Zones Function
1. Access the User Menu.
2. Press COMMANDuntilBYPASSZONES?displays.
3. PressanySelectkey.ThekeypaddisplaysZONE:-RSTBYPS.
4. ToBypassazone,enterthezonenumberandselectBYPS.
Thezonenumberautomaticallydisappearsandanewzone
number can be entered. Refer back to step 3.
5. ToResetazone,enterthezonenumberandselectRST.
Browser Feature
If you are unsure of the zone number or description, refer to
Appendix B at the back of this guide for a diagram showing you
howtousethebuilt-inBypassZonesbrowser.
Zone Monitor
Allows the system to monitor selected disarmed zones (doors,
windows, or motion detectors) and display their name at the
keypad as they are faulted. This feature could be used to monitor
an access door.
Zone Monitor works with any disarmed zone and also sounds the
keypadmonitortonewhenthezonefaults.Thezonenamedisplays
at all keypads designated for the area in your system.
YoucanplaceanycombinationofdisarmedzonesinZoneMonitor
butonlythemostrecentzonefaulteddisplays.Thedisplayedzone
nameclearsautomaticallyafterashorttimeorwhenthezoneis
armed.
Monitor (Chime) Shortcut Key
All Systems — Press 5 for 2 seconds when the system is disarmed.
Thisinitiates the Zone Monitor operation for all Exit zones in an
Area system or all zones assigned to the perimeter in a Home/
Sleep/Away, Home/Sleep/Away with Guest, or All/Perimeter
system.Thekeypad displaysMONITOR ONand chimesordisplays
MONITOROFFandnotoneissounded.
Testing your system’s burglary protection
After using the System Test function, place all zones in Zone
Monitor. Starting at the front door, go around and open and then
close each door and window. You should hear the keypad beep
eachtime.Thekeypadalsodisplaysthenameofeachzoneasits
device is opened.