34 XR150/XR350/XR550 User Guide User Menu
Browser Feature
If you are unsure of the zone number or description, refer to
Appendix B at the back of this guide for a diagram showing you
howtousethebuilt-inZoneStatusbrowser.
Bypass Zones
Allowsyoutobypassazonepriortoarming.
Bypassing is usually done when a zone cannot be restored to
normal.Asignicantbenetofbypassingazoneistoallowazone
in a faulted or bad condition to be bypassed so arming can occur.
Thefaultedzonecanbeservicedthenextday.
A zone can be bypassed only while it is disarmed. Fire, panic,
emergency,andsupervisorytypezonesarealwaysarmed,sothey
can never be manually bypassed.
Bypass Zones can also be used to reset a zone that has been
bypassed and restore it back into the system.
When Bypass Zones is selected, a report can be transmitted to
your central station.
During arming, when choosing to bypass a zone or device, there
may be a pre-programmed maximum number of zones (up to
8) that can bebypassed in an area. This limitis programmed at
installation.
Using the Bypass Zones Function
1. Access the User Menu.
2. Press COMMANDuntilBYPASSZONES?displays.
3. PressanySelectkey.ThekeypaddisplaysZONE:-RSTBYPS.
4. ToBypassazone,enterthezonenumberandselectBYPS.
Thezonenumberautomaticallydisappearsandanewzone
number can be entered. Refer back to step 3.
5. ToResetazone,enterthezonenumberandselectRST.
Browser Feature
If you are unsure of the zone number or description, refer to
Appendix B at the back of this guide for a diagram showing you
howtousethebuilt-inBypassZonesbrowser.
Zone Monitor
Allows the system to monitor selected disarmed zones (doors,
windows, or motion detectors) and display their name at the
keypad as they are faulted. This feature could be used to monitor
an access door.
Zone Monitor works with any disarmed zone and also sounds the
keypadmonitortonewhenthezonefaults.Thezonenamedisplays
at all keypads designated for the area in your system.
YoucanplaceanycombinationofdisarmedzonesinZoneMonitor
butonlythemostrecentzonefaulteddisplays.Thedisplayedzone
nameclearsautomaticallyafterashorttimeorwhenthezoneis
armed.
Monitor (Chime) Shortcut Key
All Systems — Press 5 for 2 seconds when the system is disarmed.
Thisinitiates the Zone Monitor operation for all Exit zones in an
Area system or all zones assigned to the perimeter in a Home/
Sleep/Away, Home/Sleep/Away with Guest, or All/Perimeter
system.Thekeypad displaysMONITOR ONand chimesordisplays
MONITOROFFandnotoneissounded.
Testing your system’s burglary protection
After using the System Test function, place all zones in Zone
Monitor. Starting at the front door, go around and open and then
close each door and window. You should hear the keypad beep
eachtime.Thekeypadalsodisplaysthenameofeachzoneasits
device is opened.