XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
39
AREA INFORMATION
Area Information
17.1 Area Information
Allows you to assign functions to the different areas in the system. All non-24-hour zones
must be assigned to an active area. See Zone Information.
You activate an area by assigning it a name. See Area Name. A name is given to each active
area in place of a number to assist the user during arming and disarming.
When only areas one to eight are used, the Armed Status display is 1 2 3 4 5 6 7 8. When
areas nine or higher are used the system Armed Status display reads ALL SYSTEM ON or
SYSTEM ON. Press the COMMAND key to display additional areas.
Refer to the Multiple Displays section at the beginning of this document and in the XR150/
XR350/XR550 User’s Guide (LT-1278).
17.2 Exit Delay
Enter the exit delay time for all Exit type zones in this area. When the exit delay time
starts, all activity on that zone and other non-24-hour zone types in the area is ig-
nored until the exit delay expires. The keypad displays the Exit Delay time countdown
and annunciates the Exit Delay tone at 8 second intervals until the last 10 seconds when
annunciation is at 3 second intervals.
The exit de lay can be from 30 to 250 sec onds. Default is 60 seconds.
During Exit Delay, if an exit zone trips, then restores, and trips again, the Exit Delay timer
restarts. This restart can occur only once.
Exit Error Operation: At arming, when an entry/exit zone (EX) is faulted at the end of the
exit delay then one of two sequences occur:
For Entry Delay 1 EX type zones:
• the bell sounds for the length of time set in Bell Cutoff programming.
• the Entry Delay operation starts requiring code entry to disarm
• if not disarmed, a zone alarm and an exit error are sent to the receiver.
For Entry Delay 2-4 EX type zones:
• the zone is force armed and a zone force arm message is sent to the receiver
• an Exit Error is sent to the receiver
• the bell sounds for the length of time set in Bell Cutoff programming
17.3 Burglary Bell Output
Enter the output number (0 to 6, 500 to 999, G1 to G20, D1 to D16, or F1 to F20) that is
turned on any time a Burglary type zone is placed in alarm. The output is turned off when
you disarm any area and no other Burglary type zones are in alarm. The output can also be
turned off using the Alarm Silence option in the User Menu or by entering a user code with
the authority to silence alarms. The duration of this bell output follows the time entered
in the System Options>Bell Cutoff Time option. See the Output Options - Bell Cutoff Time
section. If Bell Test is selected YES, the Burglary Bell Output entered here is turned on for
two seconds each time the system is armed.
17.4 Opening/Closing Reports
This option allows an Opening report to be sent to the receiver whenever any area is
disarmed. A Closing report is also sent to the receiver when any area is armed.
17.5 Closing Check
Select YES to enable the panel to verify that all areas in the system are armed after
permanent or extended sched ules ex pire. If the Clos ing Check nds any areas disarmed
past the sched uled time, the keypads selected to display System Trouble Status displays
CLOSING TIME! and emits a steady beep. When Area Schedules is set to YES in Area
Information, the specic area and name display followed by — LATE.
When Auto Arm is NO, if within ten minutes the system is not armed or if the schedule is
not extended, a Late to Close report is sent to the SCS-1R Receiver. When Auto Arm is YES,
the area arms. See Automatic Arming section.
If the area becomes disarmed outside of any schedule, the Closing Check sequence occurs
after the Late Arm Delay time. See Late Arm Delay.
When Closing Check is NO and Auto Arm is YES, the system immediately arms when the
schedule expires. No warning tone occurs.
In addition, when Closing Check is NO, the option to extend a schedule does not display
when the schedule expires.
17.6 Closing Code
When YES is selected, a code number is required for system arming. If NO is selected, a
code number is not required for system arming.
AREA INFORMATION
EXIT DELAY: 60
BURG BELL OUT: 0
O/C RPTS NO YES
CLS CHK NO YES
CLS CODE NO YES