XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
57
APPENDIX
Activate Cell (263C Only)
Note: (Version 109 or higher rmware) If the 263C Cellular Communicator has not been previously
activated, Automatic Cellular Activation is performed when the panel powers up or is reset. Activate
Cell (discussed below) is only necessary when Automatic Cellular Activation is not successful and
communication was not established.
To begin the cellular activation for a 263C CDMA Cellular Communicator, verify that the 263C MEID has been
added for the panel using Remote Link or by calling Customer Service (1-800-641-4282). At the keypad,
press any top row Select key when ACTIVATE CELL is displayed on the keypad. When the SURE NO YES?
conrmation menu appears press the Select key beneath YES to complete the cellular activation.
Successful Display Failure Display
CELL ACTIVATED NOT ACTIVATED
PC Programming
This allows the user to Remote Program the panel using a 399 cable attached to LX500 (J14). When the Select
Key is pressed, the panel displays PROGRAMMING... at this time the panel does not communicate with
any LX bus attached to LX500, and the 399 cable can be used to connect via Remote Link. PROGRAMMING...
will display at the keypad for the duration of the Remote Session. Once the session has ended, or if no
Remote Link connection has been established after one minute, the keypad displays RECONNECT LX BUS.
From this point, if the LX500 bus should be connected within one minute.
When using the 399 cable to program the panel, the connection type should be “Direct” and the baud rate set
to 38400. This connection may be used for all Remote Programming, including Remote Update.
Test Z-Wave Option
This feature allows the installer to test panel communication with Z-Wave devices. A successful test indicates
a response from a device. Press any top row Select key to view the Z-Wave Device List.
Press COMMAND to advance through each Z-Wave device and press any top row Select key to begin the test on
the device displayed.
The name of the device displays above the device number. The current number of successful communications
followed by the total number of attempts displays to the right of the device number. The test stops after 99
attempts.
Press COMMAND to view the nal number of successful communications.
Exiting the Diagnostics program
Press the COMMAND key until STOP displays. Press any Select key. The keypad returns to the Status List display.
22.3 Using the 984 Command Function
This feature allows connection to connect to a service receiver, which is used primarily to bring a new
account on-line and upload panel programming completed in Remote Link™.
Note: When not in the Programming Menu, the function 984 + COMMAND can be entered at the keypad, and a
remote options menu appears. This menu contains the following options:
NUMBER: Enter a phone number into the keypad for the panel to dial. Enter any required prexes and area
codes. After completing panel programming in Remote Link, set a trap to seize the panel when it calls. Traps
are set by selecting Panel > Trap. Refer to the Remote Link User’s Guide (LT-0565), or the Remote Link Help
File.
Then, from the panel, enter 984 and press the COMMAND key, while the panel is in the Status List. The keypad
display changes to NBR TEST PICKUP. Press the Select key under NBR. Enter the phone number for the service
receiver connected to the Remote Link computer. Press each number key slowly and deliberately. The panel
dials each number as it is pressed. If you make a mistake, press the Back Arrow key. The panel stops dialing
and return to the Status List.
You can enter up to 32 characters for the phone number. Once you have entered 16 characters the LCD
display is full: Press the COMMAND key to enter the nal 16 characters. To enter a # (pound sign) press the ‘0’
then the fourth (far right) Select key, and to enter an * (asterisk) press the third Select key. Program a pause
by entering the letter P. Program CID message communication by entering the letter T in the rst position.
Cancel call waiting by entering *70P as the rst characters. These characters are counted as part of the
allowable 32 characters. Press COMMAND after you enter the phone number.
The panel calls the receiver connected to Remote Link to download the new programming. Remote Link then
traps the panel.