Digital Monitoring Products XR150/XR350/XR550 Series Programming Guide
40
AREA INFORMATION
17.7 Any Bypass
When YES is selected, zones can be bypassed without a code number during the arming
sequence. A code number is always required to use the Bypass Zones option from the menu.
17.8 Area Schedules
Select YES to allow each area to follow individual sets of area schedules programmed in
the User Menu. Select NO for all areas to follow only one set of schedules in the User Menu.
See the panel User Guide to add schedules to the panel.
Note: Area Schedules are not designed to operate with All/Perimeter or
Home/Sleep/Away systems.
17.9 Early Morning Ambush (Network panels only)
Enter the number of minutes (1 to 15) before a silent alarm (Early Morning Ambush S33)
is sent to the central station using the area 1 account number. Enter 0 (zero) to disable
this option.
When a user code is entered to disarm area 1 at a keypad or reader with Access
Areas assigned to area 1, the same or different user code must be entered within the
programmed number of minutes to prevent an ambush message from being sent to the
receiver. The second user code also must have authority to disarm area 1.
In addition, a zone activation with Alarm Action Message C also cancels the Early Morning
Ambush timer and stops an Ambush message from being sent to the receiver. See Report to
Transmit section in Zone Information.
The keypad does not display any indication that the ambush timer is running.
Indications can be provided by assigning an output number to Entry Out and Ambush Out
in Output Options. Entry Out turns on one minute before the timer expires and turns off at
expiration. Ambush Out turns on at the timers’ expiration and turns off when Sensor reset
is performed.
17.10
Area Number
Enter the number of the area to program. After entering the area number, press COMMAND
to enter the area name. Only Area systems allow the area name to be changed.
Note: When All/Perimeter or Home/Sleep/Away is selected as the system type, the Area
Number does not display.
17.10.1
All/Perimeter Programming
When All/Perimeter is selected as the system type, program the Interior and Perimeter
areas as needed.
17.10.2
Home/Sleep/Away Programming
When Home/Sleep/Away is selected as the system type, program the Interior, Bedroom,
and Perimeter areas as needed.
17.11 Area Name
The area name can be up to 32 alphanumeric characters. To add an area name to the system,
press any Select key and then enter up to 32 characters for the new area name. Press COMMAND
to continue. For instructions on entering alphanumeric characters see section 1.7 Entering Alpha
Characters. Inactive areas are marked * UNUSED *. Only systems programmed for Area arming
have the option available to change the area name.
To mark an active area unused, press any top row Select key to delete the old name, then
press the COMMAND key. The programmer automatically programs the name as *UNUSED*.
If you have already cleared Area Information during Initialization, all areas are marked *
UNUSED *. See Initialization section.
Home/Sleep/Away with Guest systems display the area name, but the names cannot be
changed. The following are the display names that appear on the keypad:
Area Display Area Display Area Display
1 Perimeter 4 Guest1 Perimeter 7 Guest2 Perimeter
2 Interior 5 Guest1 Interior 8 Guest2 Interior
3 Bedrooms 6 Guest1 Bedrooms 9 Guest2 Bedrooms
17.12 Account Number
Enter the account number to be sent to the receiver for this area. Choose an account number
compatible with the Communication Type selected in Communications. The default Account
Number is the one previously entered in Communications. This account number is used when
sending area messages and events to the central station
.
See the Area Account Number
Messages in the Appendix.
ANY BYPS NO YES
AREA SCH NO YES
EARLY AMBUSH: 0
AREA NO: -
INT PERIM
INT BDRM PERIM
* UNUSED *
ACCOUNT NO: 12345