Digital Monitoring Products XR100 Series Installation Guide
4
INTRODUCTION
XR100 Series Installation Guide Digital Monitoring Products
5
INTRODUCTION
3.2 Wiring Diagram
The XR100 Series diagram below shows some of the accessory modules you can connect for use in various
applications. A brief description of each module follows in section 3.4.
Heat detectors, pull
stations, or any other
contact devices listed
for
Fire Protective
Signaling can be
connected to zones
9 and 10.
Zo
nes 9 and 10 and
Model 715 compatibility
identifier: A
Maximum operating
range: 9.7 VDC to
14.0 VDC.
Class B (Style A).
See LT-0164 for a list of
approved 4-wire smoke
detectors and power
supervision relays.
WARNING: Incorrect
connections may cause
damage to the unit.
** For UL installations, total current combined from Auxiliary
(terminals 7, 11, 25, and 27) and Bell Power (terminal 5) cannot exceed:
1.3 Amp with 50 VA transformer, 1.0 Amp Max for Auxiliary Power
1.9 Amp with 56 VA transformer, 1.0 Amp Max for Auxiliary Power and 1.5 Amp Max for Bell
DMP Transformers
Model 327 – 16.5 VAC 50 VA
Class 2 Plug-in
Model 322 – 16 VAC 56 VA
Class 2 Wire-i
n
Secondary Power Supply
1.0 Amps Max. charging current.
Use only 12 VDC rechargeable
batteries. DMP Models 365, 366,
367, 368, or 369. Replace
batteries every 3 to 5 years.
Bell **
12 VDC
Minimum cutoff time 5 min.
1.5 Amp Max
* Keypads
Models 690/690F/790/790F
77mA at 12 VDC
Model 693/793
92mA at 12 VDC
Model 630F
63mA at 12 VDC
Model 7060/7060A
80mA at 12 VDC
Model 7070/7070A
72mA at 12 VDC
Model 7063/7063A
86mA at 12 VDC
Model 7073/7073A
93mA at 12 VDC
Model 7760
65mA at 12 VDC
Minimum voltage on Auxiliary output
to process Sensor trips is 10.2 VDC.
Auxiliary Power **
Total current combined from
terminals 7, 11, 25, and 27
1.5 Amp Max
10.2 VDC to 14.0 VDC
UL Listed Resistors
1.0k Ohm - DMP Model 311
3.3k Ohm - DMP Model 309
10K Ohm - DMP Model 308
For UL Grade A
burglary applications
use Ademco Model
AB12M bell and bell
housing.
Front and Rear
tamper protection
included with
Model 350A
Attack Resistant
Enclosure.
Bell cutoff time
range is 5 to 99
minutes, non-coded.
See section 11.2 in the XR100 Series Installation Guide (LT-0899) for a
complete list of approved 2-wire smoke detectors for zones 9, 10, and
715 Zone Expansion Module zones.
AC
1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 199 20 21 22 23 24 25 26 27 2
8
+B
BELL GND SMK GNDRED YEL GRN BLK Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9+ Z9– Z10+ Z10–AC –B GND GND GNDGND
K6 K7
Output 1 Output 2
J3
Phone Line
J10
J22
LX-Bus
Bat
tery
Start
Power
LED
J8
PROG
J4
Tamper
J1
6
Reset
Out1 Out2
Outputs 3-6
J1
1
3
4
5
6
J2
"
J1
Ethernet
Link LED
Activity LED
OV
C
XR100 Series
Command Processor™
Panel
1k Ohm 1k Ohm 1k Ohm
DISARM
ARM
J23
R
L
X
Smoke
Detector
3.3k Ohm
3.3k Ohm
3.3k Ohm
3.3k Ohm
1k Ohm
Form C Relays (J2)
Output Color Code–Model 431 Harness
Output 2 N/O Orange/White
Output 2 Com White/Gray
Output 2 N/C Violet/White
Output 1 N/O Orange
Output 1 Com Gray
Output 1 N/C Violet
Annunciator Outputs (J11)
Output Color Code
Output 3
Red
Output 4 Yello
w
Output 5 Green
Output 6 Blac
k
AC Wiring must be in conduit and exit
out the left side of the enclosure.
Wiring on terminals 5 through 22 must
exit right and maintain 1/4" separation
from the AC and battery positive wiring.
Front
Tamper
Rear
Tamper
s
16 to 18 gauge wire
Maximum AC Wire distance
with 16 gauge wire: 70 feet
with 18 gauge wire: 40 feet
RED
BLACK
Cold Water
Pipe Earth
Ground
Bell
Zone 1
Zone 2
Zone
3
Zone 4
Zone 5
Zone 6
Zone 7
Zone
8
3.3k
Ohm
Resistor
3.3k
Ohm
Resistor
Zone Expander
Model 715
7mA @ 12 VDC
Models 715-8, 715-1
6
20mA @ 12 VDC
Use UL Listed Power Supervision
Relay rated at 12 VDC.
1k Ohm
s
= Supervised Circuit
Zone
9
Zone
10
22 gauge minimum
22 gauge minimum
22 gauge minimum
22 gauge minimum
RE
D
YELLOW
GREEN
BLAC
K
1k Ohm 1k Ohm
1k Ohm
Zone Expander
Model 714
7mA @ 12 VDC
Models 714-8, 714-1
6
20mA @ 12 VDC
RED
YELLOW
GREE
N
BLAC
K
RED
s
s
s
s
s
s
s
s
s
For UL installations, the Model
327 plug-in transformers shall
be installed in a DMP Model
ES501 enclosure. The plug-in
transformer shall plug into a
120 VAC 60 Hz outlet not
controlled by a switch and all
16 to 18 gauge wire
shall run
through conduit.
s
s
s
S
S
S
S
S
S
S
S
S
S
S
S
1k
Oh
m
S
S
1k
Oh
m
S
S
1k
Oh
m
S
S
1k
Ohm
S
S
1k
Oh
m
S
S
1k
Ohm
S
S
1k
Oh
m
S
S
1k
Ohm
S
S
S
S
S
S
S
S
S
S
1k Ohm
Zone Expander
(up to 8 zones)
Model 712-
8
19mA @ 12
VDC
S
S
Zone
Expander
Model 711
7mA @ 12
VDC
1k
Ohm
s
Keyswitch Arming
can be connected
to any zone. See
LT
-0681 Section 10.4.
s
s
s
s
s
s
s
s
TYPES OF SERVICE
Central Station DACT service may be provided.
See sections 29.4.
Suitable for Remote Station PPU DACT Service.
See sections 29.7. Suitable for manual fire alarm,
automatic fire alarm, sprinkler supervisory, or
water flow alarm.
Suitable for Grade AA High Line Central Station with
NET communication. See sections 23.8 and 25.8.
NFPA 72
This equipment should be installed in accordance with Chapter 11 of the National
Fire Alarm Code, ANSI/NFPA 72-2002, (National Fire Protection Association,
Bat
terymarch Park, Quincy, MA 02269). Printed information describing proper
installation, operation, testing, maintenance, evacuation planning, and repair
service is to be provided with this equipment.
POWER LIMITED
All circuits on the Model XR100 Series comply with the requirements for inherent
power limitation and are Class 2 except the red battery wire and AC terminals.
NFPA 72 OPERATING INSTRUCTIONS
The operating instructions LT-0352 must be
located adjacent to the control unit or keypad.
HOUSEHOLD FIRE WARNING
UL recognized limited energy cable must be
used for connection of all initiating, indicating,
and supplementary devices.
WARNING
THIS UNIT MAY BE PROGRAMMED TO USE AN ALARM VERIFICATION
FEAT
URE THAT RESULTS IN DELAY OF THE SYSTEM ALARM SIGNAL FROM
THE INDICATED CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS
SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER
SMOKE DETECTOR SHALL BE CONNECTED TO THESE CIRCUITS UNLESS
APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ).
Verification
Zo
nes
______
Control Unit
Delay
13.6 sec.
Smoke
Model
______
Detector
Delay
____sec.
In all applications where more than one wire
is under a terminal, the wire must be cut
and NOT looped around the screw terminal.
Zones 9, 10, and all
expanded zones are
suitable for Class B (as
applicable for the
initiating and signaling
line circuits per UL 864
Table 48.2 or 48.3).
Installation limits under
local Authority Having
Jurisdiction (AHJ).
Using verification delays
on zones 9 and 10 is
optional. Use the
delays marked on the
smoke detectors.
Grade B may be provided with dialer
communication and DMP 350A Enclosure.
See section 23.6.
Suitable for Household Fire and Grade A
Household Burglary.
Suitable for Grade A Local, Police Station
Connect, Mercantile, and Proprietary with
dialer direct communication and 350A
Enclosure. See sections 23.3, 23.5, and
23.6.
Suitable for Proprietary, PPU, other
technologies, (XR100N only), local.
SIA CP-01-2000 minimum system is
XR100 Series, UL listed local Bell, and off
premise DACT communication to an
SCS-1R receiver plus listed compatible
keypads*.
Figure 1: XR100 Series Wiring Diagram