6.8 XR100 Series Power Requirements
During AC power failure, the XR100 Series panel and all connected auxiliary devices draw their power from the
battery. All devices must be taken into consideration when calculating the battery standby capacity. The following
table lists the XR100 Series panel power requirements. You must add the additional current draw of keypads, zone
expansion modules, smoke detector output, and any other auxiliary devices used in the system for the total current
required. The total is then multiplied by the number of standby hours required to calculate the total ampere-hours
required.
Standby Battery Power Calculations Standby Current Alarm Current
XR100 Series Control Panel
Relay Outpu3ts 1-2 (ON)
Switch Grounds 3-6 (ON)
Active Zones 1-8
Active Zones 9-10
2-Wire Smoke Detectors
Panel Bell Output
Qty 1 _
Qty _______
Qty _______
Qty _______
Qty _______
Qty _______
x
180mA
30mA
5mA
1.6mA
4mA
0.1mA
180 mA
______
______
______
______
______
Qty 1 _
Qty _______
Qty _______
Qty _______
Qty _______
Qty _______
x
180mA
30mA
5mA
*2mA
30mA
0.1mA
1500mA
180 mA
______
______
______
______
______
______mA
893A Dual Phone Line Module Qty _______ x 12mA ______ Qty _______ x 50mA ______
1100X Wireless Receiver Qty _______ x 40mA ______ Qty _______ x 40mA ______
860 Relay Output Module (one relay active)
All four relays active
Qty _______ x
34mA
138mA
______
______
Qty _______ x
34mA
138mA
______
______
865 Style Y or Z Notication Module Qty _______ x 26mA ______ Qty _______ x 85mA ______
866 Style W Notication Module Qty _______ x 45mA ______ Qty _______ x 75mA ______
867 LX-Bus Style W Notication Module Qty _______ x 30mA ______ Qty _______ x 80mA ______
869 Dual Style D Initiating Module Qty _______ x 25mA ______ Qty _______ x 75mA ______
630F Remote Fire Command Center Qty _______ x 63mA ______ Qty _______ x 92mA ______
690/690F Security Command Keypad Qty _______ x 77mA ______ Qty _______ x 84mA ______
693/793 Easy Entry Keypad
Active Zones (EOL Installed)
Qty _______ x
92mA
1.6mA
______
______
Qty _______
Qty _______
x
x
120mA
*2mA
______
______
790/790F Security Command Keypad
Active Zones (EOL Installed)
Qty _______ x
77mA
1.6mA
______
______
Qty _______
Qty _______
x
x
84mA
*2mA
______
______
7060 Thinline/7060A Aqualite Keypad Qty _______ x 72mA ______ Qty _______ x 80mA ______
7063 Thinline/7063A Aqualite Keypad Qty _______ x 85mA ______ Qty _______ x 100mA ______
7070 Thinline/7070A Aqualite Keypad
Active Zones (EOL Installed)
Qty _______ x
72mA
1.6mA
______
______
Qty _______
Qty _______
x
x
87mA
*2mA
______
______
7073 Thinline/7073A Aqualite Keypad
Active Zones (EOL Installed)
Qty _______ x
85mA
1.6mA
______
______
Qty _______
Qty _______
x
x
100mA
*2mA
______
______
7760 Clear Touch Keypad Qty _______ x 65mA ______ Qty _______ x 115mA ______
733 Wiegand Interface Module
Active Zones (EOL Installed)
Annunciator (ON)
Qty _______
Qty _______
x
x
30mA
1.6mA
______
______
Qty _______
Qty _______
Qty _______
x
x
x
30mA
*2mA
20mA
______
______
______
734 Wiegand Interface Module
Active Zones (EOL Installed)
Annunciator (ON)
Qty _______
Qty _______
x
x
15mA
1.6mA
______
______
Qty _______
Qty _______
Qty _______
x
x
x
15mA
*2mA
20mA
______
______
______
Copy Sub-Totals to next page Sub-Total Standby
*Based on 10% of active zones in alarm.
______mA Sub-Total Alarm ______mA