Digital Monitoring Products XR100 Series Installation Guide
22
COMPLIANCE
XR100 Series Installation Guide Digital Monitoring Products
23
COMPLIANCE
UL 1635 Specications
Digital Burglar Alarm Communicator System Units
24.1 System Trouble Display
The Status List Display must include at least one keypad that displays system monitor troubles. See the XR100 Series
Programming Guide (LT-0896).
24.2 Digital Dialer Telephone Number
Both programmed telephone numbers must begin with a P. See the XR100 Series Programming Guide (LT-0896).
24.3 Test Time
The Test Time option must be programmed so that the XR100 Series sends a report once every 24 hours. See the
XR100 Series Programming Guide (LT-0896).
24.4 Closing Wait
The Closing Wait option must be programmed YES. See the XR100 Series Programming Guide (LT-0896).
UL 365 Specications
Police Station Connected and Local Burglar Alarm Units and Systems
25.1 System Trouble Display
The Status List Display must include at least one keypad that displays system monitor troubles. See the XR100 Series
Programming Guide (LT-0896).
25.2 Entry Delay
The maximum entry delay used must not be more than 60 seconds when using the Model 350A Grade A housing. See
the XR100 Series Programing Guide (LT-0896).
25.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds. See the XR100 Series Programming Guide (LT-0896).
25.4 Grade A Bell
A Grade A local audible signal appliance must be used such as Ademco AB12M bell and bell housing.
25.5 Bell Cutoff
The Bell Cutoff time cannot be less than 15 minutes. See the XR100 Series Programming Guide (LT-0896).
25.6 Automatic Bell Test
The Automatic Bell Test option must be programmed as YES. See the XR100 Series Programming Guide (LT-0896).
25.7 Line Security for Police Connect
Basic line security is provided when the Model XR100 Series is congured as a dialer system.
25.8 AA High Line Network Security
High Line Security is provided when congured as a NET system using an XR100N panel. The NET Check-in time
must be set from 01 to 06 minutes or AA. When programmed for UL AA (UL High Line Security) Exit Time Restart is
disabled. When a dialer is required for 06 minute check-in time, an attack resistant enclosure (DMP Model 350A)
is required. When the check-in time is set to a number less than 200 seconds, an attack resistant enclosure is not
required. See sections 3.2, 3.2.1, and 3.3 of the XR100 Series Programming Guide (LT-0896).